Showing posts with label air quality. Show all posts
Showing posts with label air quality. Show all posts

Friday, December 6, 2013

air quality alert issued for St Bernard Parish


This morning LDEQ issued an Air Quality Alert for St Bernard Parish because the level of Sulfur Dioxide concentration violated the health standard.  An SO2 alert was also issued yesterday evening.

Sensitive groups, like children, the elderly, people with COPD, respiratory issues, and asthma, should restrict outdoor activity.

""In terms of the recent exceedances, it appeared that whatever emissions overages had occurred, likely at parish refineries, had ceased by Friday afternoon.
The most recent sulfur dioxide spike above the 75 parts per billion sulfur dioxide standard at the DEQ's Chalmette Vista monitoring station was a 90 parts per billion reading, recorded at 10 a.m. Friday.
That marked the fourth exceedance since Thursday, with the highest overage being a 112 parts per billion reading at 9 p.m. Thursday."" 

http://www.nola.com/environment/index.ssf/2013/12/louisiana_deq_issues_air_quali.html
 
 
LDEQ has changed access to air monitor data. 

Hourly readings are now accessible at http://airquality.deq.louisiana.gov/Data  
Select Ch_Vista or Meraux and select Date
Hourly readings for Valero's Ventura Drive monitor are accessible here: http://lena.providenceeng.com/Hourly.aspx

 


 

Sunday, February 3, 2013

Ozone in St Bernard Parish, Louisiana

St Bernard Parish Air Quality


UNLESS ................................................
“Unless someone like you cares a whole awful lot,
Nothing is going to get better. It's not.”
― Dr. Seuss, The Lorax


Ozone is formed when nitrates of oxygen (NOx) and volatile organic compounds (VOCs) combine together in sunlight. One solution to high concentrations of ground level ozone is the use of fuel that contains less benzene and lower sulfur content. Some communities switch public transportation buses and school buses to bio diesel or natural gas or use ultra low sulfur content fuels in an attempt to reduce Ozone pollution.

Ozone Attainment Status


The Good News on Ozone levels in St Bernard is there seems to be enough lead time to address the Ozone issue before being designated or labeled non-attainment for Ozone. It's a violation of the Ozone standard when the 8-hour average of ground level ozone does not remain below the current standard of 75 parts per billion. (The old standard was an 8-hour average of 80 parts per billion). An area would be recommended for designation (or "labeled") non-attainment when the annual fourth-highest daily maximum 8-hour concentration of Ozone, averaged over 3 years, is 75 ppb or higher. http://www.epa.gov/air/criteria.html In St Bernard Parish, Ozone levels are sampled at the LDEQ "Meraux" site at Joe Davies Elementary School.

According to data on EPA's Air Data website, St Bernard Parish's current 3 year average for Ozone is around 73 ppb and we all need to do our part to keep it below 75 ppb. (Based on annual fourth highest daily maximum 8 hour concentration of Ozone for 2010 at 74 ppb , for 2011 at 76 ppb , for 2012 at 69ppb. { [(74+76+69) / 3 ] = 73 ppb} From http://www.epa.gov/airdata/ left hand column menu, select Monitor Values, select Ozone, select Louisiana, select year, scroll down to 8-hour averages.) LDEQ's "Meraux" site readings assessible here , under site data, select "Meraux".
.
So, now is the time for all of us to do our part to be part of the solution, to work with coalitions to reduce Ozone, and to protect what little is left of our good air quality. Part of success stories, like St Bernard's in the late 1990's and Baton Rouge's recent success to reduce Ozone, are coalitions that take "Early Action" to reduce pollution before its so bad. For Ozone, this would include even further reduction of NOx (nitrates of oxygen) and VOCs (volatile organic compounds such as benzene, ethylbenzene, toluene, xylene and others) at all nearby industries, and the use of "Clean Fuels" in buses, trucks and other vehicles, including barge and ship traffic on the Mississippi River.

Clean Fuels create dirty neighborhoods

But Ozone and Clean Fuel Projects are sort of a Catch 22 in communities where the Clean Fuel is manufactured. When EPA mandates lower benzene and sulfur content in Clean Fuels, the refining of crude oil into "Clean Fuels" results in more sulfur dioxide and VOCs, such as benzene, in the fenceline neighborhoods, unless the LDEQ requires more stringent pollution controls. It seems Clean Fuels Projects that began around the late 1990's, or early 2000, were "grandfathered in" and LDEQ didnot require the state-of-the-art pollution controls. The result: St Bernard Parish is now the poster child for sulfur dioxide pollution, with concentration levels three times higher than the one-hour sulfur health limit, the 2nd highest sulfur dioxide concentrations in the United States, second only to Hawaiin communities that seem to be around active volcanoes.  The EPA is expected to make its official designation of St Bernard Parish as non-attainment for sulfur dioxide health standards.

Calcined petroleum coke (CPC) also contributes sulfur emissions. Louisiana is the largest CPC producing region  in the world outside of China, with several Rain CII coke plants accounting for more than half of Louisiana’s CPC production. Rain CII's facility in Chalmette operates under a variance and has received several additional exemptions to bypass the pyroscrubber and vent emissions for upto 500 hours a year. Rain CII Chalmette recently applied for a "minor" modification to its Title V air permit to make the variance permanent and to increase the total of bypass or vent time to 836 hours. This "minor" application is separate from its December 2012 short-term variance for 336 hours that LDEQ pulled in January 2013 admist concerns of high sulfur levels in the adjacent neighborhood.  As a "minor" modification, the Title V air permit is subject to less stringent pollution controls than "major" modifications.  Minor modifications do not require pubic notice or a cost benefit analysis. St Bernard Parish Government has requested LDEQ conduct a public hearing on the "minor" modification at Rain CII. This will be a good opportunity for concerned people and government bodies, such as the HRQL, to submit pubic comment.

sulfur dioxide concentrations

St Bernard Parish Air Quality

UNLESS ................................................
 
“Unless someone like you cares a whole awful lot,
Nothing is going to get better. It's not.”
― Dr. Seuss, The Lorax

 


Sulfur Dioxide Status


The Louisiana Department of Environmental Quality recommended EPA designate St Bernard Parish air quality non-attainment for sulfur dioxide   (SO2).  EPA is expected to make its official designation on June 3, 2013.  LDEQ must submit a State Implementation Plan (SIP) by mid-2014; the SIP must demonstrate the area will reach attainment by 2017.  Ambient air monitors display hourly averages for sulfur dioxide.  It is a health violation when the one-hour average is 75 parts per billion (ppb) SO2 or higher.  An area is considered non-attainment when the 3 year average of the 99th percentile of hourly average readings is 75 ppb or higher.  According to EPA's AirData website,  St. Bernard's current SO2 3 year average of the 99th percentiles is 255 ppb (two hundred fifty-five)  and it needs to be 75 ppb or lower.  Clearly there is alot a work ahead to bring sulfur dioxide pollution levels down.

BUT that is not the whole picture. Complete perimeter monitoring and more stringent pollution controls are paramount to the goal of reducing sulfur dioxide emissions.  The readings in the EPA data bank are samples or readings when the wind is just right to make a direct hit or "air strike" on the monitor. There is a real need for perimeter or fenceline monitoring. We should demand more air monitors, perhaps placing additional monitors back on Mehle Avenue and back in Algiers on the west bank. Maybe adding monitors on the east side of ExxonMobil's refinery, perhaps around Lloyds Ave, sort of in-line with the Chalmette Vista monitor that is on E Chalmette Circle, and another one on the east side of Valero Energy's refinery, but not as far east as the Meraux monitor at Joe Davies School. 
As an example:

From the Chalmette High School monitor data 2007 - 2011, the maximum hourly readings for each year were  95, 116, 54, 80, and 85 ppb SO2.  Although the SO2 standard back then was a 24-hour average of 140 ppb and an annual limit of 30 ppb,  the 3 year average was 64 ppb, approaching the current one-hour average 75 ppb limit. (The three year average of the last three available annual 99th percentiles is 64 parts per billion).   

From the Meraux monitor data 2008 - 2012, the maxmium hourly readings for each year were 161, 36, 29, 58, and 59 ppb SO2. There seems to be an upward trend in sulfur dioxide concentrations in Meraux.  In 2009, Murphy Oil installed interm, temporary pollution controls while in settlement talks with Concerned Citizens.  The resultant EPA consent decree requires the new owner, Valero Energy, install a Flare Gas Recovery System by 2017, operate an air monitor on Ventura Drive in Chalmette, reduce various pollution emissions,  increase on-site monitoring, and provide for public forums.  In the meantime, Murphy Oil installed a benzene saturation unit without state-of-the-art pollution controls, adding to both the sulfur concentrations and VOC emissions.  There is pending citizen enforcement action on the benzene unit.  Valero Energy recently received a "minor" modification permit to revamp and expand the hydrocracker unit to increase production without more stringent pollution controls; this will result in even more sulfur dioxide pollution.  In 2013, the EPA will require "Tier 3" Mandate compliance for even lower sulfur content in gasoline products.  Both Valero Energy and ExxonMobil refineries will have to modify their plants to comply.  If those modifications do not require more stringent pollution controls, the result will be increased sufur dioxide and VOCs.

The Valero Energy Ventura Drive monitor is not part of the EPA databank, and does not provide maxium reading data, although that information is available in the public forums.  Valero Energy's Ventura monitor has its own share of sulfur health violations.  

So, the problem is all over, and not just in Chalmette Vista. 
.




From the Chalmette Vista site, 2007 - 2012 the air quality in that neighborhood had a total of 298 sulfur health violations, just in 2011 alone.  Maximum hourly average readings for each year (2007 - 2012) were 477, 363, 373, 378, 375, and 242 SO2.  Residents residing in Chalmette Vista are suffering the health effects and "unless someone like you cares a whole awful lot,Nothing is going to get better. It's not."
 
It is imperative our community take action to reduce sulfur dioxide concentrations.  Perimeter monitoring and more stringent pollution controls are paramount to this goal. 
 



Two of the oil refinery plants in St Bernard Parish operate under an EPA consent decree, both results of Citizen Enforcement Action by residents of St Bernard Parish. Any State Plan to reduce sulfur emissions in St Bernard Parish, will be reviewed by EPA.  The other plant, the coke plant, operates on a variance for up to 500 hour bypass and recently applied to LDEQ to permanently increase that bypass to 836 hours. SBPG recently requested a public hearing on that permit (for Rain CII Carbon) and that will be an excellent opportunity for the HRQL an other government officials to submit public comments to the LDEQ.


Sulfur Dioxide data and analysis available at EPA's AirData site,  under Monitor Values .

Mehle Avenue, Arabi
2000 through 2005: Total number of sulfur health violations 102

(Number of sulfur health violations 15, 19, 7, 12, 34, and 15 for each respective year)

Annual 99th percentiles sulfur dioxide 108, 141, 89, 93, and 161, and 177 ppb for each respective year. Maximum hourly average readings 124, 191, 127, 138, 305, and 184 ppb for each respective year. The 3 year average based on the last annual 99th percentiles would have been 143 ppb, well over the current 75 ppb standard.

Algiers (Orleans Parish) "Entergy" site
2006 - 2007 : Total number of sulfur health violations not counted by LDEQ because the Algiers site was part of a special monitoring project.

Maxium hourly average readings 154 ppb and 306 ppb SO2. There is a clear need for monitoring in these west bank communities.
Monitoring information for the Algiers "Entergy" site on the westbank of the Mississippi River is not included in the EPA databank. It is available in the LDEQ Air Quality 2009 Report (link below). This Algiers air monitor was located on property owned by Entergy Corporation.  The "Entergy" site, along with the Chalmette Vista and Chalmette High School air monitors were made possible through the hard work and dedication of Mr. Ken Ford, founding president of St Bernard Citizens for Environmental Quality, his neighbors, and the Louisiana Bucket Brigade. http://www.deq.louisiana.gov/portal/Portals/0/AirQualityAssessment/Analysis/Data/Chalmette-Report--Final,%202009.pdf
The EPA website does not include data for the Chalmette High School and the Chalmette Vista sites for 2005 and 2006 due to insuffient number of readings because of down time from Hurricane Katrina. More information on these sites is included in the LDEQ Air Monitor Report 2009 at the link above.
Chalmette High School
2007 through 2011: Total number of sulfur health violations 7  The EPA website does not include the 2005 and 2006 data due to insufficient number of readings because of down time in the aftermath of Hurricane Katrina.  More information is included in the LDEQ 2009 Report . 

( Number of sulfur health violations 2, 3, 0, 1, and 1 for each respective year)

Annual 99th percentiles sulfur dioxide 67, 73, 49, 57, and 85 ppb for each respective year. Maximum hourly average readings 95, 116, 54, 80, and 85 ppb for each respective year.  Maximum hourly average reading in 2006 was 95 ppb, per the LDEQ 2009 Report . 
The 3 year average based on the last available annual 99th percentiles would have been 64 parts per billion. This was a sign that we were approaching non-attainment. If a monitor could be added east of ExxonMobil, but not as far as Chalmette High School, there would be a clearer indication of sulfur concentrations in that area.

Chalmette Vista E. Chalmette Circle

2007 through 2012: Total number of sulfur health violations 1,321  The EPA website does not include the 2005 and 2006 data due to insufficient number of readings because of down time in the aftermath of Hurricane Katrina. More information is included in the LDEQ 2009 Report .

( Number of sulfur health violations 211, 233, 284, 206, 298, and 89 for each respective year)

Annual 99th percentiles sulfur dioxide 349, 330, 314, 248, 300, and 217 ppb SO2 for each respective year. Maximum hourly average readings 477, 363, 373, 378, 375, and 242 ppb SO2 for each respective year. Maximum reading in 2006 was 271, per LDEQ 2009 Report

The current 3 year average (of the 99th percentile) at Chalmette Vista is 255 ppb.  We need to get the sulfur concentrations to below 75 ppb to be in attainment for sulfur dioxide.

Meraux Mistrot Drive Joe Davies School

2008 through 2012: Total number of sulfur health violations 2

(Number of sulfur health violations 2, 0, 0, 0, and 0 for each respective year)

Annual 99th percentiles sulfur dioxide 49, 24, 24, 30, and 29 ppb SO2 for each respective year. Maximum hourly average readings 161, 36, 29, 58, and 59 ppb SO2 for each respective year.

The current 3 year average (of the 99th percentile) at Meraux is 28 ppb SO2, and trending upward, with increasing maximum hourly averages each year.

 

Friday, January 4, 2013

Air Quality Report for 2012


  2012 Air Quality Report for St Bernard Parish

St. Bernard Parish air quality failed to meet pollution standards in 2012 for sulfur dioxide on 29 days, for PM2.5 on 34 days, for PM10 on six days, and for hydrogen sulfide on eight days. 

Based on air samples at three community air monitors , there were 170 days or 45% of the year when residents had to suffer acute exposure level of sulfur dioxide at 10 parts per billion (ppb) or higher. Sulfur dioxide levels failed to meet EPA's 75 ppb  one-hour health standard on 29 days. 
 
All too often the hydrogen sulfide levels failed to meet the EPA recommended daily exposure level of 1.4 ppb.  On eight days, the hydrogen sulfide levels failed to meet a health standard of 30 ppb -- this is the health standard in the State of California; the State of Louisiana has no such limit.  On 17 days, hydrogen sulfide levels reached 20 ppb or higher.

Particulate matter PM2.5 failed to meet the EPA daily standard of 35 micrograms per cubic meter of air (ug/m3) on 34 days; PM10 failed to meet the EPA daily standard of 150 ug/m3 on six days.

Ozone readings were higher than EPA's standard of 75 ppb on eight days.  The only air quality alerts from DEQ in 2012 were for "Ozone Action Days" and during a persistent marsh fire in January 2012. 

Data excludes the month of January and the fireworks timeline for July Fourth and New Year's Eve.

2012 Monthly Air Quality Readings

2012-RECAP- Air-Quality-in-St-Bernard-Parish



DEQ's 'Meraux' site air monitor at Joe Davies Elementary School


Report copy Here:  Air Quality in 2012 in St Bernard Parish, LA

The air in St. Bernard Parish failed to meet PM2.5 pollution limits on at least 34 days, with high readings of 69 ug/m3, 67 ug/m3, and 61 ug/m3 at DEQ’s ‘Ch_Vista’ site, well above the 35 ug/m3 standard.

PM10  readings failed to meet pollution limits on at least two days in Chalmette Vista with high readings of 167 ug/m3 and 150 ug/m3; and, on four days at Valero Energy’s Ventura Drive site with high readings of 238 ug/m3, 187 ug/m3, 183 ug/m3, 166 ug/m3, and 153 ug/m3,, well above the 150 ug/m3 standard .
Air quality in St. Bernard Parish failed to meet the one-hour sulfur health standard of 75 ppb on 29 days, with some of the highest readings at DEQ’s ‘Ch_Vista’site of 241 ppb, 229 ppb, 216 ppb, 211 ppb, 184 ppb, 174 ppb, 164 ppb, and 148 ppb. 

The sulfur levels at Valero Energy’s Ventura Drive site failed to meet the health standard on one day with 120 ppb, and had 34 days of acute exposure level of 10 ppb or higher, with five days of sulfur readings at 30 ppb or higher. Some of the higher sulfur readings at Valero Energy’s Ventura Drive site were 120 ppb, 48 ppb, 45 ppb and 41 ppb. The DEQ ‘Meraux’ site at Joe Davies Elementary school had 47 days of acute exposure level of 10 ppb or higher and three days of 30 ppb or higher, with some of its highest readings at 59 ppb, 43 ppb, and 33 ppb.
In 2012 the highest hydrogen sulfide reading was 78 ppb at the Valero Energy's Ventura Drive site, which also had four additional days that failed to meet the 30 ppb health limit.  Some of the higher readings at Valero Energy's Ventura Drive site were 78 ppb, 62 ppb, 44 ppb and 35 ppb. 

DEQ's 'Ch_Vista' site had twelve days of hydrogen sulfide readings above 20 ppb, with four days that failed to meet the 30 ppb health limit.  Some of the higher Chalmette Vista readings were 53 ppb, 49 ppb, 46 ppb, and 43 ppb. DEQ’s ‘Meraux’ site at Joe Davies Elementary school had high hydrogen sulfide readings of 27 ppb and 20 ppb.

Data excludes the month of January and the fireworks timelines of July Fourth and New Year's Eve.

Sunday, December 23, 2012

Chalmette Home Buyers


Potential home buyers can check various Quality of Life and other indexes for Chalmette, LA

Home Facts Community Information



Air Quality on a scale of 1 to 10  >>>>   2.9

Details day by day


Home Facts details State by State to check facts before you purchase a home

Saturday, December 22, 2012

air quality report December 2012




Based on the Louisiana Department of Environmental Quality (DEQ)’s and Valero Energy’s 2012 air monitor readings   , one would say the air quality in St. Bernard Parish is considerably poor.  It fails to meet current standards for sulfur dioxide (SO2), hydrogen sulfide (H2S), and particulate matter pollution (PM2.5 and PM10), and is likely to exceed protective screening levels.  Monitoring is a valuable tool to measure offsite effects from major sources.  More stringent pollution controls and enforcement of existing regulations is still needed to protect public health.
 

On December 21, 2012 the Algiers to Chalmette Ferry turned around due to a suspicion of a chemical release from the ExxonMobil and Rain CII Carbon industrial area in Chalmette Vista, according to  WWL TV News and           The Times Picayune .

DEQ has an air monitor in the Chalmette Vista neighborhood.  If the wind direction last night was towards the ferry, the "Ch_Vista" air monitor would not pickup those levels, as the air monitor is in the opposite direction. DEQ used to monitor the air on the west bank side of the Mississippi River, but dismantled the monitor after Hurricane Gustav in 2008.  Currently, there are three community monitors in St Bernard Parish.

Over the years, on-site monitors at ExxonMobil's oil refinery in Chalmette have shown the effects from the adjacent Rain CII Carbon petroleum coke plant. In a report to DEQ, ExxonMobil's monitored concentrations were reported above the occupational exposure limit of 0.5 parts per million (ppm) or 500 parts per billion (ppb) during 2011 and 2012, in DEQ document 8364090 .  The health standard for ambient air is 0.075 ppm or 75 ppb sulfur dioxide.


Pollution levels in Chalmette Vista fail to meet the health standards for sulfur dioxide (75 parts per billion) and particluate matter sized 2.5 micrometers or PM2.5 (35 ug/m3).  In Chalmette Vista, some of the higher readings this year for sulfur dioxide have been 229.3 ppb, 164.4ppb, and 138.5 ppb [well above 75 ppb].    At the Valero Energy monitor, the highest reading was 120 ppb SO2 and at the Meraux monitor was 59 ppb. 

In December alone high readings for SO2 at "Ch_Vista" were 108 ppb and 143 ppb (both on Dec 9th) and 241 ppb and 184 ppb (both on Dec 10th). For PM2.5 for the year, high readings have been 88 ug/m3 and 67 ug/m3[ well above 35 ug/m3]. This does NOT include data from January's marsh fire. Yet, variances and emission increases continue to be issued in St. Bernard Parish by DEQ without requiring updated pollution controls.

When sulfur dioxide combines with particulate matter, it alters the lung defenses and causes breathing problems, wheezing, chest tightness, and shortness of breath. It can lead to premature death.

Hydrogen sulfide levels have been high as well. Exposure to lower concentrations of hydrogen sulfide causes eye irritation, sore throat, cough, nausea, shortness of breath, and fluid in the lungs. Long-term, low-level exposure causes fatigue, loss of appetite, headaches, poor memory, dizziness, loss of teeth and anemia. It affects the nervous system and cellular respiration.

Residents of St. Bernard Parish are frequently exposed to hydrogen sulfide readings that fail to meet the EPA recommend daily exposure limit of 1.4 ppb (0.0014 ppm). EPA’s intermediate exposure level to this poisonous gas is 20 ppb; the acute exposure level is 70 ppb. The State of California health limit for hydrogen sulfide is 30 ppb; Louisiana has no such limit.

For the year 2012, some of the higher hydrogen sulfide readings at Ch_Vista were 62 ppb, 53 ppb, and 49 ppb.  Valero Energy's monitor's highest reading for 2012 was 78 ppb.  The highest reading at DEQ's Meraux monitor was 40 ppb.

In December 2012 alone, the DEQ's monitor in Chalmette Vista had high readings of hydrogen sulfide at 18 ppb (Dec 9th), 21 ppb (Dec 16th), and 29 ppb (Dec 10th & Dec 17th).

This Chamlette Vista  monitor is located at a neighborhood playground. DEQ does not issue community alerts when pollution levels are high.  The only time DEQ issued community alerts for air quality in St Bernard Parish was in the January marsh fire or for Ozone Action Days, when ground level ozone was expected to cause health concerns.

.

Tuesday, October 2, 2012

September 2012 air quality readings

Updated through month end:
Some of the higher air quality readings in September 2012 from the three air monitors in St. Bernard Parish; data accessible at these links.

LDEQ Ch_Vista Site select site data, select Ch_Vista
Valero's Ventura Site current link
LDEQ Meraux Site select site data, select Meraux





Shown above, location of the three community air monitors : LDEQ's sites at Ch_Vista and Meraux, and Valero's site at Ventura. The former "Entergy", across the river, was shut down after Hurricane Gustav in 2008 as was the former Chalmette High site, closed in 2009. These closures were based on the previous sulfur standards and perhaps would still be operating if based on the new one-hour health standard limit of 75 parts per billion sulfur dioxide.

Above photo from LDEQ's 2009 report on St. Bernard's air quality



The EPA recommended1.4 parts per billion (ppb) daily exposure to hydrogen sulfide (H2S) was exceeded throughout the month.…..inhaling more than this concentration on a daily basis poses an appreciable risk of deleterious effects.
http://www.epa.gov/iris/toxreviews/0061tr.pdf . "Exposure to lower concentrations can result in eye irritation, a sore throat and cough, nausea, shortness of breath, and fluid in the lungs." "Long-term, low-level exposure may result in fatigue, loss of appetite, headaches, irritability, poor memory, and dizziness."

The State of California air quality standard limits hydrogen sulfide to 30 ppb H2S; that standard was surpassed at all three sites, with the highest reading of 62 ppb H2S at Ventura. The State of Louisiana has no such standard.

The EPA health standard for sulfur dioxide (SO2) is 75 ppb SO2.
St. Bernard Parish is non-attainment for the sulfur health standard.  On September 29th and 30th sulfur levels exceeded health standards with some of the highest readings at 229 ppb SO2.   According to Louisiana DEQ, when sulfur dioxide levels reach 12 ppb SO2 it triggers headaches and adverse health and quality of life. Sulfur dioxide levels were at or above this adverse level on ten days this month.

The standard for particulate matter PM2.5 is 35; that standard was violated twice this month.

benzene and 1, 3-butadiene cause no odors at lower concentrations but are great health concern for long time exposure enen in lower concentrations." - LDEQ 2009 St Bernard Air Monitoring Project Final Report

Below are some of the higher air quality readings for the month of September 2012.







 
September 2012
Air Quality Readings
St. Bernard Parish
Hydrogen Sulfide
and Sulfur Dioxide
health standards
SO2   75 ppb
H2S    1.4 ppb EPA recommended daily 
PM2.5   35
9/1/2012 no data Hurricane Isaac
9/1 - 9/4 no PM10 data








9/2/2012 noon Ventura 8 ppb SO2
1pm Ventura 6 ppb SO2
2pm Ventura 10 ppb SO2
3pm Ventura 9 ppb SO2
4pm Ventura 12 ppb SO2
  5pm Meraux 10 ppb H2S
6pm Ch_Vista 5 ppb H2S
  Meraux 11 ppb H2S
7pm Ch_Vista 6 ppb H2S
  Meraux 18 ppb H2S
8pm Ch_Vista 8 ppb H2S
9pm Ch_Vista 6 ppb H2S
  Ventura 8 ppb H2S
10pm Ch_Vista 5 ppb H2S
Ventura 8 ppb H2S
11pm Ch_Vista 6 ppb H2S
 
9/3/2012 midnight Ch_Vista 7 ppb H2S
Ventura 6 ppb H2S
1am Ch_Vista 6 ppb H2S
Ventura 7 ppb H2S
2am Ch_Vista 7 ppb H2S
Ventura 8 ppb H2S
3am Ch_Vista 9 ppb H2S
Ventura 8 ppb H2S
4am Ch_Vista 7 ppb H2S
Ventura 9 ppb H2S
5am Ch_Vista 7 ppb H2S
    Ventura 8 ppb H2S
6am Ch_Vista 6 ppb H2S
  Ventura 8 ppb H2S
7am Ventura 8 ppb H2S
Ch_Vista PM2.5 - 21
8am Ventura 5 ppb H2S
9am Ch_Vista 6 ppb H2S
10am Ch_Vista 5 ppb H2S
6pm Ch_Vista 4 ppb H2S
7pm Ch_Vista 5 ppb H2S
Ch_Vista PM2.5 - 56
8pm Ch_Vista 7 ppb H2S
9pm Ch_Vista 8 ppbH2S
10pm Ch_Vista 8 ppb H2S
Ventura 5 ppb H2S
11pm Ch_Vista 8 ppb H2S
  Ventura 7 ppb H2S
9/4/2012 midnight Ch_Vista 8 ppb H2S
Ventura 7 ppb H2S
Meraux 5 ppb H2S
1am Ch_Vista  -- --
Ventura 7 ppb  H2S
Meraux 5 ppb H2S
2am Ch_Vista 10 ppb H2S
Ventura 7 ppb H2S
Meraux 7 ppb H2S
3am Ch_Vista 9 ppb H2S
Ventura 9 ppb H2S
Meraux 9 ppb H2S
4am Ch_Vista 8 ppb H2S
Ventura 9 ppb H2S
Meraux 10 ppb H2S
5am Ch_Vista 7 ppb H2S
Ventura 8 ppb H2S
Meraux 13 ppb H2S
6am Ch_Vista 6 ppb H2S
Ventura 8 ppb H2S
7am Ch_Vista 4 ppb H2S
Ventura 5 ppb H2S
Ventura 6 ppb SO2
Meraux 4 ppb H2S
  Meraux 11 ppb SO2
8am Ventura 14 ppb SO2
5pm Ventura PM10  - 45
7pm Ch_Vista 6 ppb H2S
Ventura 7 ppb SO2
8pm Ch_Vista 5 ppb H2S
9pm Ch_Vista 6 ppb H2S
Ventura 5 ppb H2S
10pm Ch_Vista 7 ppb H2S
Ventura 4 ppb H2S
11pm Ch_Vista 5 ppb H2S
Ventura 6 ppb H2S
9/5/2012 Midnight Ch_Vista 4 ppb H2S
Ventura 5 ppb H2S
1am Ventura 4 ppb H2S
Ventura 8 ppb SO2
2am Ch_Vista 8 ppb H2S
Ventura 3 ppb H2S
    Meraux 4 ppb H2S
3am Ch_Vista 7 ppb H2S
  Meraux 3 ppb H2S
4am Ch_Vista 5 ppb H2S
Ventura 14 ppb SO2
Ventura PM10 -38
  Meraux 23.2 ppb SO2
5am Ch_Vista 4 ppb H2S
Ventura 17 ppb SO2
  Meraux 12.5 ppb SO2
6am Ch_Vista  5 ppb H2S
7am Ch_Vista 5 ppb H2S
3pm Ventura PM10  -39
1pm Ch_Vista PM10 -36
Ch_Vista PM2.5 - 20
6pm Ventura PM10 - 39
8pm Ch_Vista PM10 -36
9pm Meraux 5 ppb H2S
10pm Ch_Vista 5 ppb H2S
Ventura 5 ppb H2S
Meraux 7 ppb H2S
11pm Ch_Vista 10 ppb H2S
Ventura 9 ppb H2S
Meraux 6 ppb H2S
9/6/2012 midnight Ch_Vista 8 ppb H2S
Ventura 9 ppb H2S
Meraux 7 ppb H2S
1am Ch_Vista 6 ppb H2S
Ventura 14 ppb H2S
Meraux 11 ppb H2S
2am Ch_Vista 6 ppb H2S
Ventura 11 ppb H2S
Meraux 11 ppbH2S
3am Ch_Vista 6 ppb H2S
Ventura 7 ppb H2S
Meraux 6 ppb H2S
4am Ch_Vista 8 ppb H2S
Ventura 5 ppb H2S
Meraux 5 ppb H2S
5am Ch_Vista 8 ppb H2S
Ventura 8 ppb H2S
Meraux 8 ppb H2S
6am Ch_Vista 11 ppb H2S
Ventura 9 ppb H2S
Meraux 6 ppb H2S
7am Ch_Vista 14 ppb H2S
Ch_Vista PM10  -25
Ventura 8 ppb H2S
Meraux 4 ppb H2S
8am Ch_Vista 7 ppb H2S
11am Ventura 11 ppb SO2
9/7/2012 10am Ventura 9 ppb SO2
11am Ventura 5 ppb SO2
9/8/2012 1am Meraux 6 ppb H2S
  3am Ch_Vista 6 ppb H2S
4am Ch_Vista 6 ppb H2S
5am Ch_Vista 4 ppb H2S
Meraux 5 ppb H2S
6am Ch_Vista 8 ppb H2S
  Meraux 5 ppb H2S
  7am Ch_Vista 4 ppb H2S
9am Ventura 7 ppb H2S
11am Ch_Vista PM2.5  -19
  Ventura PM10 -38
1pm Ch_Vista PM10  -35
5pm Ventura PM10 - 44
9/9/2012 1am Ventura 7 ppb H2S
2am Ch_Vista 8 ppb H2S
Ventura 5 ppb H2S
3am Ch_Vista 9 ppb H2S
4am Ch_Vista 6 ppb H2S
5am Ch_Vista 4 ppb H2S
Ventura 5 ppb H2S
Meraux 4 ppb H2S
6am Ch_Vista 4 ppb H2S
Ventura 8 ppb H2S
Meraux 5 ppb H2S
7am Ch_Vista 6 ppb H2S
Ventura 8 ppb H2S
8am Ch_Vista 6 ppb H2S
Ventura 5 ppb H2S
3pm Ch_Vista PM2.5 - 20
7pm Meraux 5 ppb H2S
8pm Ch_Vista 5 ppb H2S
Meraux 7 ppb H2S
9pm Ch_Vista 9 ppb H2S
Ventura 6 ppb H2S
10pm Ch_Vista 7 ppb H2S
Ventura 6 ppb H2S
11pm Ch_Vista 6 ppb H2S
Ventura 4 ppb H2S
 
9/10/2012 3am Meraux 7.6 ppb SO2
4am Meraux 5.9 ppb SO2
5am Meraux 7.7  ppb SO2
6am Meraux 8.5 ppb SO2
7am Ventura 8 ppb SO2
Meraux 8.1 ppb SO2
8am Ventura 6 ppb SO2
3pm Ch_Vista PM2.5 - 21
7pm Ch_Vista PM10  -35
8pm Ventura PM10 - 67
9/11/2012 1am Meraux 3 ppb H2S
Ch_Vista PM2.5 - 22
2am Ch_Vista 8 ppb H2S
    Ventura 5 ppb H2S
Ventura PM10  -58
Meraux 14 ppb H2S
3am Ch_Vista 11 ppb H2S
   Ventura 5 ppb H2S
Meraux 7 ppb H2S
4am Ch_Vista 20 ppb H2S
Ventura 9 ppb H2S
5am Ch_Vista 9 ppb H2S
Ventura 10 ppb H2S
6am Ch_Vista 7 ppb H2S
Ventura 7 ppb H2S
7am Ch_Vista 5 ppb H2S
Ch_Vista PM10  -37
Ventura 4 ppb H2S
2pm Ch_Vista PM2.5 - 26
6pm Ch_Vista PM2.5 - 21
   
9/12/2012 6am Ch_Vista 7 ppb H2S
Ch_Vista PM10 -33
Meraux 23 ppb SO2
7am Ch_Vista 6 ppb H2S
    Ventura 5 ppb H2S
10am Ch_Vista PM2.5 -33
9/13/2012 6am Ch_Vista 4 ppb H2S
9am Ch_Vista PM10 -29
3pm Ch_Vista PM2.5 - 21
9/14/2012 3am Ch_Vista 5 ppb H2S
4am Ch_Vista 5 ppb H2S
8am Ch_Vista PM10  -30
11am Ch_Vista PM2.5 - 22
  1pm Meraux 8 ppb SO2
2pm Meraux 8.6 ppb SO2
3pm Meraux 6.5 ppb SO2
4pm Ch_Vista PM2.5 - 28
9pm Ventura PM10  - 30
9/15/2012 midnight Ch_Vista 5 ppb H2S
1am Ch_Vista 5 ppb H2S
2am Ch_Vista 6 ppb H2S
3am Ch_Vista 6 ppb H2S
4am Ch_Vista 6 ppb H2S
Ventura  7 ppb H2S
5am Ch_Vista 6 ppb H2S
Ventura 6 ppb H2S
6am Ch_Vista 6 ppb H2S
Ventura 5 ppb H2S
7am Ch_Vista 5 ppb H2S
9am Meraux 11.1 ppb SO2
10am Meraux 8 ppb SO2
1pm Ch_Vista PM2.5 -27
9/16/2012 midnight Ch_Vista 5 ppb H2S
1am Ventura 6 ppb H2S
3am Ch_Vista 6 ppb H2S
4am Ch_Vista 5 ppb H2S
5am Ch_Vista 5 ppb H2S
9/17/2012 5am Ch_Vista 9 ppb H2S
    Meraux 4 ppb H2S
6am Ch_Vista 17 ppb H2S
Ventura 6 ppb H2S
Meraux 5 ppb H2S
7am Ch_Vista 12 ppb H2S
Ventura 9 ppb H2S
Meraux 14 ppb H2S
8am Ch_Vista 10 ppb H2S
Ventura 16 ppb H2S
Meraux 4 ppb H2S
9am Ch_Vista 11 ppb H2S
Ventura 6 ppb H2S
Meraux 3 ppb H2S
10am Ch_Vista 49 ppb H2S
Ch_Vista 34.7 ppb SO2
Ventura 5 ppb H2S
Meraux 40 ppb H2S
11am Ch_Vista 34 ppb H2S
Ventura 62 ppb H2S
Meraux 11 ppb H2S
noon Ch_Vista 18 ppb H2S
  Ventura 21 ppb H2S
Meraux 9 ppb H2S
1pm Ch_Vista 10 ppb H2S
Ch_Vista 15.4 ppb SO2
Ventura 14 ppb H2S
2pm Ch_Vista 5 ppb H2S
Ventura 6 ppb H2S
3pm Ch_Vista 6 ppb H2S
Ventura 7 ppb H2S
4pm Ch_Vista 7 ppb H2S
Ch_Vista 21 ppb SO2
5pm Ch_Vista 5 ppb H2S
Ch_Vista 25.6 ppb SO2
Ventura 8 ppb H2S
6pm Ch_Vista 5 ppb H2S
7pm Ch_Vista 5 ppb H2S
Ventura 8 ppb H2S
   
9/18/2012 Ventura 1am to 8am 1am Ventura 8 ppb SO2
2am Ventura 8 ppb SO2
Meraux 15.5 ppb SO2
3am Ventura 8 ppb SO2
Meraux 8.9 ppb SO2
4am Ventura 7 ppb SO2
Meraux 6.7 ppb SO2
5am Ventura 8 ppbSO2
Meraux 11.5 ppb SO2
6am Ventura 19 ppb SO2
Meraux 13.7 ppb SO2
7am Ch_Vista PM10  -30
  Ventura 13 ppb SO2
  Meraux 8.9 ppb SO2
8am Ventura 7 ppb SO2
6pm Ch_Vista PM2.5 - 22

9/19/2012 midnight Ch_Vista 4 ppb H2S
  Ventura 6 ppb H2S
  2am Ch_Vista 6 ppb H2S
3am Ch_Vista 4 ppb H2S
4am Ch_Vista 5 ppb H2S
5am Ch_Vista 7 ppb H2S
6am Ch_Vista 5 ppb H2S
7am Ch_Vista 4 ppb H2S
8am Ch_Vista 4 ppb H2S
8pm Ch_Vista 4 ppb H2S
Ventura PM10 -58
9pm Ch_Vista 5 ppb H2S
10pm Ch_Vista 5 ppb H2S
11pm Ch_Vista 4 ppb H2S
     
9/20/2012 midn Ch_Vista 4 ppb H2S
1am Ch_Vista 5 ppb H2S
2am Ch_Vista 5 ppb H2S
3am Ch_Vista 5 ppb H2S
Ch_Vista 8.1 ppb SO2
Meraux 6.9 ppb SO2
4am Ch_Vista 5 ppb H2S
Ch_Vista 19.2 ppb SO2
Ventura 6 ppb SO2
Meraux 11.3 ppb SO2
5am Ch_Vista 4 ppb H2S
Ch_Vista 19.7 ppb SO2
Ventura 10 ppb SO2
Meraux 9.3 ppb SO2
6am Ch_Vista 4 ppb H2S
Ch_Vista 16.5 ppb SO2
Ventura 8 ppb SO2
Meraux 10.2 pps SO2
7am Ch_Vista 4 ppb H2S
Ch_Vista 7.5 ppb SO2
Ventura 11 ppb SO2
Meraux 6.4 ppb SO2
8am Ch_Vista 7.5 ppb SO2
Meraux 7.5 ppb SO2
1pm Ch_Vista PM10 -30
3pm Ch_Vista PM10  -38
6pm Ch_Vista 4 ppb H2S
7pm Ch_Vista 6 ppb H2S
Ch_Vista PM2.5 - 24
8pm Ch_Vista 6 ppb H2S
Ch_Vista 9.3 ppb SO2
Ch_Vista PM2.5 - 24
Ventura PM10  -34
9pm Ch_Vista 5 ppb H2S
10pm Ch_Vista 5 ppb H2S
Ch_Vista PM10  - 35
11pm Ch_Vista 6 ppb H2S
Ventura PM10 - 41
9/21/2012 midn Ch_Vista 8 ppb H2S
Ch_Vista PM10 -30
Ventura 5 ppb H2S
Meraux 7 ppb H2S
1am Ch_Vista PM2.5 - 20
  Ventura 12 ppb H2S
Meraux 9 ppb H2S
2am Ch_Vista 14 ppb H2S
Ventura 18 ppb H2S
Meraux 7 ppb H2S
3am Ch_Vista 11 ppb H2S
Ventura 14 ppb H2S
Ventura PM10 - 37
Meraux 5 ppb H2S
4am Ch_Vista 10 ppb H2S
Ventura 8 ppb H2S
Meraux 7 ppb H2S
5am Ch_Vista 7 ppb H2S
Ventura 9 ppb H2S
6am Ch_Vista 5 ppb H2S
Ch_Vista PM10  -43
Ventura 6 ppb H2S
7am Ch_Vista 4 ppb H2S
Ch_Vista PM10  -32
9am Ch_Vista PM2.5  -23
noon Ch_Vista PM2.5  -24
  3pm Ch_Vista PM2.5 - 25
7pm Ch_Vista 5 ppb H2S
8pm Ventura PM10 - 38
11pm Ch_Vista 5 ppb H2S
9/22/2012 midn Ch_Vista 6 ppb H2S
1am Ch_Vista 7 ppb H2S
  Ventura 6 ppb H2S
2am Ch_Vista 6 ppb H2S
  Ventura 6 ppb H2S
Meraux 5 ppb H2S
3am Ch_Vista 7 ppb H2S
  Ventura 7 ppb H2S
Meraux 6 ppb H2S
4am Ch_Vista 12 ppb H2S
  Ventura 9 ppb H2S
Meraux 9 ppb H2S
5am Ch_Vista 13 ppb H2S
  Ventura 10 ppb H2S
Meraux 7 ppb H2S
6am Ch_Vista 8 ppb H2S
  Ventura 8 ppb H2S
7am Ch_Vista 5 ppb H2S
  Ventura 7 ppb H2S
8am Meraux 9.2 SO2
7pm Ch_Vista 8 ppb H2S
8pm Ch_Vista 10 ppb H2S
9pm Ch_Vista 13 ppb H2S
  Ventura PM10 - 53
10pm Ch_Vista 13  ppb H2S
  Ventura  12 ppb H2S
  Meraux 13 ppb H2S
11pm Ch_Vista 15 ppb H2S
  Ventura 16 ppb H2S
Meraux 15 ppb H2S
9/23/2012 midn Ventura 21 ppb H2S
Meraux 10 ppb H2S
1am Ventura 16 ppb H2S
2am Ventura 10 ppb H2S
Meraux 6 ppb H2S
6am Meraux 7 ppb H2SS
6pm Ch_Vista 4 ppb H2S
7pm Ch_Vista 8 ppb H2S
Ch_Vista 14.8 ppb SO2
8pm Ch_Vista 12 ppb H2S
Ch_Vista 38.1 ppb SO2
9pm Ch_Vista 16 ppb H2S
Ch_Vista 70.6 ppb SO2
10pm Ch_Vista 17 ppb H2S
Ch_Vista 20.9 ppb SO2
  Ventura 9 ppb H2S
Meraux 6 ppb H2S
11pm Ch_Vista 17 ppb H2S
Ch_Vista 7.7 ppb SO2
  Ventura 17 ppb H2S
Meraux 11 ppb H2S
9/24/2012 midn Ch_Vista 16 ppb H2S
Ventura 35 ppb H2S
Meraux 15 ppb H2S
1am Ch_Vista 18 ppb H2S
Ventura 28  ppb H2S
Meraux 17  ppb H2S
2am Ch_Vista 16 ppb H2S
Ventura 21 ppb H2S
  Meraux 13 ppb H2S
3am Ch_Vista 12 ppb H2S
Ventura 16 ppb H2S
Meraux 10 ppb H2S
4am Ch_Vista 9 ppb H2S
Ventura 12 ppb H2S
Meraux 8 ppb H2S
5am Ventura 9 ppb H2S
Ventura PM10 - 57
6am Ventura 6 ppb H2S
7am Ventura 7 ppb H2S
Ventura PM10  - 67
8am Ventura 5 ppb H2S
11am Ventura PM10  - 78
7pm Ventura PM10 -- 57
 
9/25/2012 midn Ch_Vista 5 ppb H2S
2am Ch_Vista 4 ppb H2S
Meraux 6 ppb H2S
3am Ch_Vista 5 ppb H2S
4am Ch_Vista 4 ppb H2S
    Ventura 5 ppb H2S
5am Ch_Vista 5 ppb H2S
  Ventura 4 ppb H2S
6am Ch_Vista 5 ppb H2S
Ch_Vista PM10  - 44
  Ventura 6 ppb H2S
7am Ventura PM10 -- 75
8am Ventura PM10 -- 69
8pm Ventura 4 ppb H2S
9pm Ventura 4 ppb H2S
10pm Ventura 5 ppb H2S
11pm Ventura 5 ppb H2S





9/26/2012 midn Ch_Vista 6 ppb H2S
2am Ch_Vista 7 ppb H2S
Meraux 5 ppb H2S
  3am Ch_Vista 5 ppb H2S
  Meraux 5  ppb H2S
5am Ch_Vista 5 ppb H2S
11am Ch_Vista 13.6 ppb SO2
noon Ch_Vista 10.6 ppb SO2
  Ventura PM10 -- 43
11pm Ventura PM10  -51
9/27/2012 midn Ch_Vista 4 ppb H2S
     Ventura PM10 - 75
1am Ch_Vista 4 ppb H2S
2am Ch_Vista 4 ppb H2S
  Ventura 5 ppb H2S
  Ventura PM10 -105
3am Ch_Vista 4 ppb H2S
  Ventura 4 ppb H2S
  Ventura PM10 -93
4am Ch_Vista 4 ppb H2S
5am Ch_Vista 4 ppb H2S
6am Ch_Vista 4 ppb H2S
9/28/2012 midn Ventura 5 ppb H2S
  2am Ch_Vista 5 ppb H2S
5am Ventura 5 ppb H2S
10am Ch_Vista 25.8 ppb SO2
11am Ch_Vista 23.3 ppb SO2
3pm Ch_Vista 6 ppb H2S
Ch_Vista 21.4 ppb SO2
4pm Ch_Vista 6 ppb H2S
10pm Ch_Vista 4 ppb H2S
Ch_Vista 52.3 ppb SO2
11pm Ch_Vista 4 ppb H2S
Ch_Vista 18.6 ppbSO2
9/29/2012 midn Ch_Vista 5 ppb H2S
Ch_Vista 31.4 ppb SO2
5am Ch_Vista 7 ppb H2S
Ch_Vista 44.2 ppb SO2
    Ventura 4 ppb H2S
6am Ch_Vista 11 ppb H2S
Ch_Vista 62.6 ppb SO2
7am Ch_Vista 7 ppb H2S
8am Ch_Vista 6 ppb H2S
Ventura 4 ppb H2S
9am Ch_Vista 6 ppb H2S
Ch_Vista 35.9 ppb SO2
10am Ch_Vista 8 ppb H2S
Ch_Vista75.7 ppb SO2
11am Ch_Vista 7 ppb H2S
Ch_Vista 74 ppb H2S
noon Ch_Vista 6 ppb H2S
Ch_Vista 54.2  ppb SO2
1pm Ch_Vista 6 ppb H2S
Ch_Vista 23.5 ppb SO2
2pm Ch_Vista 5 ppb H2S
3pm Ch_Vista 5 ppb H2S
4pm Ch_Vista 5 ppb H2S
5pm Ch_Vista 5 ppb H2S
6pm Ch_Vista 5 ppb H2S
Ventura 4 ppb H2S
7pm Ch_Vista 5 ppb H2S
8pm Ch_Vista 5 ppb H2S
9pm Ch_Vista 4 ppb H2S
10pm Ch_Vista 4 ppb H2S
11pm Ch_Vista 4 ppb H2S
9/30/2012 midn Ch_Vista 4 ppb H2S
3am Ch_Vista 5 ppb H2S
4am Ch_Vista 5 ppb H2S
5am Ch_Vista 6 ppb H2S
6am Ch_Vista 6 ppb H2S
Ch_Vista 28.2 ppb SO2
7am Ch_Vista 9 ppb H2S
Ch_Vista 125.2 ppbSO2
8am Ch_Vista 6 ppb H2S
Ch_Vista 15.1 ppb SO2
9am Ch_Vista 5 ppb H2S
10am Ch_Vista 12 ppb H2S
Ch_Vista 146.4 ppb SO2
11am Ch_Vista 4 ppb H2S
noon Ch_Vista 9 ppb H2S
Ch_Vista 94.8 ppb SO2
1pm Ch_Vista 10 ppb H2S
Ch_Vista 148.9 ppbSO2
2pm Ch_Vista 11 ppb H2S
Ch_Vista 229.3 ppb SO2
3pm Ch_Vista 7 ppb H2S
Ch_Vista 59 ppb SO2
4pm Ch_Vista 9 ppb H2S
Ch_Vista 146.3 ppb SO2
5pm Ch_Vista 5 ppb H2S
6pm Ch_Vista 8 ppb H2S
Ch_Vista 97.6 ppb SO2
7pm Ch_Vista 5 ppb H2S
Ch_Vista 12.2 ppb SO2
8pm Ch_Vista 6 ppb H2S
9pm Ch_Vista 6 ppb H2S
10pm Ch_Vista 4 ppb H2S
11pm Ch_Vista 4 ppb H2S
..

.





Blog Archive